Website intended for professional users with knowledge or professional experience that enable the use of SmartFlags for their intended purpose.

I declare that:

Thank You

Thank you for placing an order for SmartFlag by APOLLO – innovative solution for all-on-x cases

Back to homepage

Submit order Book a demo

Temporary restoration for immediate loading of implants.

Milled or printed

Case no. 1

Case no. 1

Protocol 01/ If you have a printer or milling machine
in your clinic, and your CAD designer
prepares the design online.

01 / Dentist

Do the intraoral scans using Scanbody SmartFlag and send them to the laboratory.

02 / Technician

Download the library containing Scanbody SmartFlag and Multi Titanium Base. Make sure to use proper library for chosen length S/M/L while using Multi Titanium Base.

03 / Technician

Design the restoration using received scans and downloaded library.

04 / Technician

Send the design to the Dentist.

05 / Dentist

Print or mill the restoration based on the design received from the Technician.

06 / Dentist

Adjust Multi Titanium Base by cutting it to the proper length (S/M/L) adapted to the design and attach them to the restoration.

07 / Dentist

Screw the restoration into the patient’s mouth intraoperatively.

Protocol 02/ If you have a lab in your clinic or
you cooperate with local technician.

01 / Dentist

Do the intraoral scans using Scanbody SmartFlag and send them to the laboratory.

02 / Technician

Download the library containing Scanbody SmartFlag and Multi Titanium Base. Make sure to use proper library for chosen length S/M/L while using Multi Titanium Base.

03 / Technician

Print or mill the restoration based on the prepared design. Adjust Multi Titanium Base by cutting it to proper length (S/M/L) adapted to the design and attach them to the restoration.

04 / Technician

Hand over the final restoration to the Doctor.

05 / Dentist

Collect the case from the technician and screw it into the patient’s mouth intraoperatively.

Protocol

1/2

Required components

Scanbody SmartFlag by APOLLO

Scanbody SmartFlag by APOLLO

Multi Titanium Base

Multi Titanium Base

Multi Titanium Base multiSHIFT36°

Multi Titanium Base multiSHIFT36°

Libraries CAD/CAM

Full-contour structure on multi-unit abutments using Multi Titanium Base.

Materials: PMMA/PEEK/ZrO₂

Case no. 2

Case no. 2

Protocol

01 / Dentist

Do the intraoral scans using Scanbody SmartFlag and send them to the laboratory.

02 / Technician

Download the library containing Scanbody SmartFlag and Multi Titanium Base. Make sure to use proper library for chosen length S/M/L while using Multi Titanium Base.

03 / Technician

Mill the structure by yourself or in a milling centre recommended by APOLLO (try-in is recommended before the final restoration).

04 / Technician

Adjust Multi Titanium Base by cutting it to proper length (S/M/L) adapted to the design.

05 / Technician

Complete the prosthetic work on the structure according to the dentist’s order.

06 / Technician

Attach the adjusted Multi Titanium Base to the restoration and hand it over to the dentist.

07 / Dentist

Collect the restoration from the technician and screw it into the patient’s mouth.

Required components

Scanbody SmartFlag by APOLLO

Scanbody SmartFlag by APOLLO

Multi Titanium Base

Multi Titanium Base

Multi Titanium Base multiSHIFT36°

Multi Titanium Base multiSHIFT36°

One Lock Digital Analog - Jeśli chcesz użyć modelu do protokołu

One Lock Digital Analog - in case of using printed model

Libraries CAD/CAM

Full-contour structure from within multi-unit abutments on titanium bar.

Materials: PMMA/PEEK/ZrO₂

Case no. 3

Case no. 3

Protocol

01 / Dentist

Do the intraoral scans using Scanbody SmartFlag and send them to the laboratory.

02 / Technician

Download the library for Scanbody SmartFlag by APOLLO and design the case using received scans.

03 / Technician

Design the structure: titanium and full-contour part at the same time (try in is recommended before final restoration).

04 / Technician

Mill the structure by yourself or in a milling centre recommended by APOLLO.

05 / Technician

Complete the prosthetic work on the structure according to the dentist’s order and hand it over to the doctor’s office.

06 / Dentist

Collect the restoration from the technician and screw it into the patient's mouth.

Required components

Scanbody SmartFlag by APOLLO

Scanbody SmartFlag by APOLLO

One Lock Digital Analog - Jeśli chcesz użyć modelu do protokołu

One Lock Digital Analog - in case of using printed model

Libraries CAD/CAM

Structure for veneering on multi-unit abutments with the usage of Multi Titanium Base/Multi Titanium Base multiSHIFT36°.

Materials: Ti/CoCr/PEEK/ZrO₂
Facing materials: acrylic/composite/ceramics

Case no. 4

Case no. 4

Protocol

01 / Dentist

Do the intraoral scans using Scanbody SmartFlag and send them to the laboratory.

02 / Technician

Download the library containing Scanbody SmartFlag, Multi Titanium Base / Multi Titanium Base MultiShift 36 and One Lock Digital Analog. Make sure to use proper library for chosen length S/M/L while using Multi Titanium Base.

03 / Technician

Design the structure using received scans and downloaded library.

04 / Technician

Mill the structure by yourself or in a milling centre recommended by APOLLO (try-in is recommended before the final work).

05 / Technician

Adjust Multi Titanium Base by cutting it to proper length (S/M/L) adapted to the design.

06 / Technician

Design a digital model using library for One Lock Digital Analog and print it.

06 / A

Place the One Lock Digital Analog in the model using a dedicated tightening screwdriver.

07 / Technician

Complete the prosthetic work on the structure according to the dentist’s order.

08 / Technician

Attach the adjusted Multi Titanium Base to the restoration and hand it over to the dentist.

09 / Dentist

Collect the restoration from the technician and screw it into the patient’s mouth.

Required components

Scanbody SmartFlag by APOLLO

Scanbody SmartFlag by APOLLO

Multi Titanium Base

Multi Titanium Base

Multi Titanium Base multiSHIFT36°

Multi Titanium Base multiSHIFT36°

One Lock Digital Analog - Jeśli chcesz użyć modelu do protokołu

One Lock Digital Analog - in case of using printed model

Libraries CAD/CAM

Structure for veneering from within multi-unit abutments on titanium bar.

Materials: Ti/CoCr/PEEK/ZrO₂
Facing materials: acrylic/composite/ceramics

Case no. 5

Case no. 5

Protocol

01 / Dentist

Do the intraoral scans using Scanbody SmartFlag and send them to the laboratory.

02 / Technician

Download the library containing Scanbody SmartFlag and One Lock Digital Analog.

03 / Technician

Design the case using received scans and downloaded library.

04 / Technician

Mill the structure by yourself or in a milling centre recommended by APOLLO ( try-in is recommended before final restoration).

05 / Technician

Design a digital model using One Lock Digital Analog library and print it.

05 / A

Place the One Lock Digital Analog in the model using a dedicated tightening screwdriver.

06 / Technician

Complete the prosthetic work on the structure according to the dentist’s order and hand it over to the doctor’s office.

07 / Dentist

Collect the final restoration from the technician and screw it into the patient's mouth.

Required components

Scanbody SmartFlag by APOLLO

Scanbody SmartFlag by APOLLO

One Lock Digital Analog - Jeśli chcesz użyć modelu do protokołu

One Lock Digital Analog - in case of using printed model

Libraries CAD/CAM

Retention bar for removable restoration on multi-unit abutments.

Materials: Ti

Case no. 6

Case no. 6

Protocol

01 / Dentist

Do the intraoral scans using Scanbody SmartFlag and send them to the laboratory.

02 / Technician

Download library for Scanbody SmartFlag by APOLLO and use it to design the bar (try in is recommended before final restoration).

03 / Technician

Mill the bar by yourself or in the milling centre recommended by APOLLO, and deliver the bar to the doctor’s office.

04 / Dentist

Collect the bar from the technician and screw it into the patient's mouth.

05 / Dentist

Complete the protocol in digital or analog way.

Required components

Scanbody SmartFlag by APOLLO

Scanbody SmartFlag by APOLLO

One Lock Digital Analog - Jeśli chcesz użyć modelu do protokołu

One Lock Digital Analog - in case of using printed model

Libraries CAD/CAM

Retention bar for removable restoration using Multi Titanium Base.

Materials: Ti/Zr

Case no. 7

Case no. 7

Protocol

01 / Dentist

Do the intraoral scans using Scanbody SmartFlag and send them to the laboratory.

02 / Technician

Download library for Scanbody SmartFlag by APOLLO and Multi Titanium Base / Multi Titanium Base Multishift 36°. Make sure to use proper library for chosen length S/M/L while using Multi Titanium Base.

03 / Technician

Design the bar based on received scans and downloaded library (try-in is recommended before final restoration).

04 / Technician

Mill the bar by yourself or in a milling center recommended by APOLLO.

05 / Technician

Adjust Multi Titanium Base by cutting it to proper length (S/M/L) adapted to the design and attach it to the bar.

06 / Technician

Hand over the bar to the dentist.

07 / Dentist

Collect the bar from the technician and screw it into the patient's mouth.

08 / Dentist

Complete the protocol in digital or analog way.

Required components

Scanbody SmartFlag by APOLLO

Scanbody SmartFlag by APOLLO

Multi Titanium Base

Multi Titanium Base

Multi Titanium Base multiSHIFT36°

Multi Titanium Base multiSHIFT36°

One Lock Digital Analog - Jeśli chcesz użyć modelu do protokołu

One Lock Digital Analog - in case of using printed model

Libraries CAD/CAM

    Scanbody SmartFlag by APOLLO

    Scanbody SmartFlag

    8 pieces including screw

    Choose the implant system

    Quantity

    Price

    1349 €

    Multi Titanium Base

    Multi Titanium Base

    Titanium base including screw

    Choose the implant system

    Quantity

    Price

    49 €

    Multi Titanium Base Multishift 36°

    Multi Titanium Base multiSHIFT36°

    Titanium base with angulated screw channel up to 36° including screw

    Choose the implant system

    Quantity

    Price

    72 €

    One Lock Digital Analog - Jeśli chcesz użyć modelu do protokołu

    One Lock Digital Analog

    Digital analog

    Choose the implant system

    Quantity

    Price

    38 €

    Śrubokręt APOLLO multiSHIFT36°

    multiSHIFT36° Screwdriver

    Screwdriver for angulated screw channel up to 36°

    Length

    Quantity

    Price

    56 €

    Śrubokręt do One Lock Digital Analog

    Handle for screwdriver

    Handle manufactured by APOLLO compatible with e.g. multiSHIFT36° screwdriver

    Quantity

    Price

    56 €

    Śrubokręt do One Lock Digital Analog

    One Lock Digital Analog Screwdriver

    Screwdriver for digital analog

    Quantity

    Price

    21 €

    Śruba kliniczna do Multi Titanium Base

    Clinical Screw Muli-unit

    Choose the implant system

    Quantity

    Price

    17 €

    Śruba laboratoryjna do Multi Titanium Base

    Laboratory Screw Muli-unit

    Choose the implant system

    Quantity

    Price

    17 €

    Śruba kliniczna do przekierowań kąta do 36° do Multi Titanium Base multiSHIFT36°

    Clinical Screw Muli-unit multiSHIFT36°

    Choose the implant system

    Quantity

    Price

    21 €

    Śruba laboratoryjnado przekierowań kąta do 36° do Multi Titanium Base multiSHIFT36°

    Laboratory Screw Muli-unit multiSHIFT36°

    Choose the implant system

    Quantity

    Price

    21 €

    Scanbody Multi-unit

    Scanbody Multi-unit

    Scanbody with an anti-reflex surface adapted to work with laboratory scanners. It includes an integrated screw that facilitates working.

    Wybierz system implantologiczny

    Quantity

    Price

    55 €

    Delivery

     60 €

    ALL PRICES DO NOT INCLUDE TAX

    Billing data

    Shipping data

    TOTAL: 0