Website intended for professional users with knowledge or professional experience that enable the use of SmartFlags for their intended purpose.

I declare that:



    Submit order Book a demo

    Temporary restoration for immediate loading of implants.

    Milled or printed

    Case no. 1

    Case no. 1

    Protocol 01/ If you have a printer or milling machine
    in your clinic, and your CAD designer
    prepares the design online.

    01 / Dentist

    Do the intraoral scans using Scanbody SmartFlag and send them to the laboratory.

    02 / Technician

    Download the library containing Scanbody SmartFlag and Multi Titanium Base. Make sure to use proper library for chosen length S/M/L while using Multi Titanium Base.

    03 / Technician

    Design the restoration using received scans and downloaded library.

    04 / Technician

    Send the design to the Dentist.

    05 / Dentist

    Print or mill the restoration based on the design received from the Technician.

    06 / Dentist

    Adjust Multi Titanium Base by cutting it to the proper length (S/M/L) adapted to the design and attach them to the restoration.

    07 / Dentist

    Screw the restoration into the patient’s mouth intraoperatively.

    Protocol 02/ If you have a lab in your clinic or
    you cooperate with local technician.

    01 / Dentist

    Do the intraoral scans using Scanbody SmartFlag and send them to the laboratory.

    02 / Technician

    Download the library containing Scanbody SmartFlag and Multi Titanium Base. Make sure to use proper library for chosen length S/M/L while using Multi Titanium Base.

    03 / Technician

    Print or mill the restoration based on the prepared design. Adjust Multi Titanium Base by cutting it to proper length (S/M/L) adapted to the design and attach them to the restoration.

    04 / Technician

    Hand over the final restoration to the Doctor.

    05 / Dentist

    Collect the case from the technician and screw it into the patient’s mouth intraoperatively.

    Protocol

    1/2

    Required components

    Scanbody SmartFlag by APOLLO

    Scanbody SmartFlag by APOLLO

    Multi Titanium Base

    Multi Titanium Base

    Multi Titanium Base multiSHIFT36°

    Multi Titanium Base multiSHIFT36°

    Libraries CAD/CAM

    Full-contour structure on multi-unit abutments using Multi Titanium Base.

    Materials: PMMA/PEEK/ZrO₂

    Case no. 2

    Case no. 2

    Protocol

    01 / Dentist

    Do the intraoral scans using Scanbody SmartFlag and send them to the laboratory.

    02 / Technician

    Download the library containing Scanbody SmartFlag and Multi Titanium Base. Make sure to use proper library for chosen length S/M/L while using Multi Titanium Base.

    03 / Technician

    Mill the structure by yourself or in a milling centre recommended by APOLLO (try-in is recommended before the final restoration).

    04 / Technician

    Adjust Multi Titanium Base by cutting it to proper length (S/M/L) adapted to the design.

    05 / Technician

    Complete the prosthetic work on the structure according to the dentist’s order.

    06 / Technician

    Attach the adjusted Multi Titanium Base to the restoration and hand it over to the dentist.

    07 / Dentist

    Collect the restoration from the technician and screw it into the patient’s mouth.

    Required components

    Scanbody SmartFlag by APOLLO

    Scanbody SmartFlag by APOLLO

    Multi Titanium Base

    Multi Titanium Base

    Multi Titanium Base multiSHIFT36°

    Multi Titanium Base multiSHIFT36°

    One Lock Digital Analog - Jeśli chcesz użyć modelu do protokołu

    One Lock Digital Analog - in case of using printed model

    Libraries CAD/CAM

    Full-contour structure from within multi-unit abutments on titanium bar.

    Materials: PMMA/PEEK/ZrO₂

    Case no. 3

    Case no. 3

    Protocol

    01 / Dentist

    Do the intraoral scans using Scanbody SmartFlag and send them to the laboratory.

    02 / Technician

    Download the library for Scanbody SmartFlag by APOLLO and design the case using received scans.

    03 / Technician

    Design the structure: titanium and full-contour part at the same time (try in is recommended before final restoration).

    04 / Technician

    Mill the structure by yourself or in a milling centre recommended by APOLLO.

    05 / Technician

    Complete the prosthetic work on the structure according to the dentist’s order and hand it over to the doctor’s office.

    06 / Dentist

    Collect the restoration from the technician and screw it into the patient's mouth.

    Required components

    Scanbody SmartFlag by APOLLO

    Scanbody SmartFlag by APOLLO

    One Lock Digital Analog - Jeśli chcesz użyć modelu do protokołu

    One Lock Digital Analog - in case of using printed model

    Libraries CAD/CAM

    Structure for veneering on multi-unit abutments with the usage of Multi Titanium Base/Multi Titanium Base multiSHIFT36°.

    Materials: Ti/CoCr/PEEK/ZrO₂
    Facing materials: acrylic/composite/ceramics

    Case no. 4

    Case no. 4

    Protocol

    01 / Dentist

    Do the intraoral scans using Scanbody SmartFlag and send them to the laboratory.

    02 / Technician

    Download the library containing Scanbody SmartFlag, Multi Titanium Base / Multi Titanium Base MultiShift 36 and One Lock Digital Analog. Make sure to use proper library for chosen length S/M/L while using Multi Titanium Base.

    03 / Technician

    Design the structure using received scans and downloaded library.

    04 / Technician

    Mill the structure by yourself or in a milling centre recommended by APOLLO (try-in is recommended before the final work).

    05 / Technician

    Adjust Multi Titanium Base by cutting it to proper length (S/M/L) adapted to the design.

    06 / Technician

    Design a digital model using library for One Lock Digital Analog and print it.

    06 / A

    Place the One Lock Digital Analog in the model using a dedicated tightening screwdriver.

    07 / Technician

    Complete the prosthetic work on the structure according to the dentist’s order.

    08 / Technician

    Attach the adjusted Multi Titanium Base to the restoration and hand it over to the dentist.

    09 / Dentist

    Collect the restoration from the technician and screw it into the patient’s mouth.

    Required components

    Scanbody SmartFlag by APOLLO

    Scanbody SmartFlag by APOLLO

    Multi Titanium Base

    Multi Titanium Base

    Multi Titanium Base multiSHIFT36°

    Multi Titanium Base multiSHIFT36°

    One Lock Digital Analog - Jeśli chcesz użyć modelu do protokołu

    One Lock Digital Analog - in case of using printed model

    Libraries CAD/CAM

    Structure for veneering from within multi-unit abutments on titanium bar.

    Materials: Ti/CoCr/PEEK/ZrO₂
    Facing materials: acrylic/composite/ceramics

    Case no. 5

    Case no. 5

    Protocol

    01 / Dentist

    Do the intraoral scans using Scanbody SmartFlag and send them to the laboratory.

    02 / Technician

    Download the library containing Scanbody SmartFlag and One Lock Digital Analog.

    03 / Technician

    Design the case using received scans and downloaded library.

    04 / Technician

    Mill the structure by yourself or in a milling centre recommended by APOLLO ( try-in is recommended before final restoration).

    05 / Technician

    Design a digital model using One Lock Digital Analog library and print it.

    05 / A

    Place the One Lock Digital Analog in the model using a dedicated tightening screwdriver.

    06 / Technician

    Complete the prosthetic work on the structure according to the dentist’s order and hand it over to the doctor’s office.

    07 / Dentist

    Collect the final restoration from the technician and screw it into the patient's mouth.

    Required components

    Scanbody SmartFlag by APOLLO

    Scanbody SmartFlag by APOLLO

    One Lock Digital Analog - Jeśli chcesz użyć modelu do protokołu

    One Lock Digital Analog - in case of using printed model

    Libraries CAD/CAM

    Retention bar for removable restoration on multi-unit abutments.

    Materials: Ti

    Case no. 6

    Case no. 6

    Protocol

    01 / Dentist

    Do the intraoral scans using Scanbody SmartFlag and send them to the laboratory.

    02 / Technician

    Download library for Scanbody SmartFlag by APOLLO and use it to design the bar (try in is recommended before final restoration).

    03 / Technician

    Mill the bar by yourself or in the milling centre recommended by APOLLO, and deliver the bar to the doctor’s office.

    04 / Dentist

    Collect the bar from the technician and screw it into the patient's mouth.

    05 / Dentist

    Complete the protocol in digital or analog way.

    Required components

    Scanbody SmartFlag by APOLLO

    Scanbody SmartFlag by APOLLO

    One Lock Digital Analog - Jeśli chcesz użyć modelu do protokołu

    One Lock Digital Analog - in case of using printed model

    Libraries CAD/CAM

    Retention bar for removable restoration using Multi Titanium Base.

    Materials: Ti/Zr

    Case no. 7

    Case no. 7

    Protocol

    01 / Dentist

    Do the intraoral scans using Scanbody SmartFlag and send them to the laboratory.

    02 / Technician

    Download library for Scanbody SmartFlag by APOLLO and Multi Titanium Base / Multi Titanium Base Multishift 36°. Make sure to use proper library for chosen length S/M/L while using Multi Titanium Base.

    03 / Technician

    Design the bar based on received scans and downloaded library (try-in is recommended before final restoration).

    04 / Technician

    Mill the bar by yourself or in a milling center recommended by APOLLO.

    05 / Technician

    Adjust Multi Titanium Base by cutting it to proper length (S/M/L) adapted to the design and attach it to the bar.

    06 / Technician

    Hand over the bar to the dentist.

    07 / Dentist

    Collect the bar from the technician and screw it into the patient's mouth.

    08 / Dentist

    Complete the protocol in digital or analog way.

    Required components

    Scanbody SmartFlag by APOLLO

    Scanbody SmartFlag by APOLLO

    Multi Titanium Base

    Multi Titanium Base

    Multi Titanium Base multiSHIFT36°

    Multi Titanium Base multiSHIFT36°

    One Lock Digital Analog - Jeśli chcesz użyć modelu do protokołu

    One Lock Digital Analog - in case of using printed model

    Libraries CAD/CAM

      Scanbody SmartFlag by APOLLO

      Scanbody SmartFlag

      8 pieces including screw

      Choose the implant system

      Quantity

      Price

      1349 €

      Multi Titanium Base

      Multi Titanium Base

      Titanium base including screw

      Choose the implant system

      Quantity

      Price

      49 €

      Multi Titanium Base Multishift 36°

      Multi Titanium Base multiSHIFT36°

      Titanium base with angulated screw channel up to 36° including screw

      Choose the implant system

      Quantity

      Price

      72 €

      One Lock Digital Analog - Jeśli chcesz użyć modelu do protokołu

      One Lock Digital Analog

      Digital analog

      Choose the implant system

      Quantity

      Price

      38 €

      Śrubokręt APOLLO multiSHIFT36°

      multiSHIFT36° Screwdriver

      Screwdriver for angulated screw channel up to 36°

      Length

      Quantity

      Price

      56 €

      Śrubokręt do One Lock Digital Analog

      Handle for screwdriver

      Handle manufactured by APOLLO compatible with e.g. multiSHIFT36° screwdriver

      Quantity

      Price

      56 €

      Śrubokręt do One Lock Digital Analog

      One Lock Digital Analog Screwdriver

      Screwdriver for digital analog

      Quantity

      Price

      21 €

      Śruba kliniczna do Multi Titanium Base

      Clinical Screw Muli-unit

      Choose the implant system

      Quantity

      Price

      17 €

      Śruba laboratoryjna do Multi Titanium Base

      Laboratory Screw Muli-unit

      Choose the implant system

      Quantity

      Price

      17 €

      Śruba kliniczna do przekierowań kąta do 36° do Multi Titanium Base multiSHIFT36°

      Clinical Screw Muli-unit multiSHIFT36°

      Choose the implant system

      Quantity

      Price

      21 €

      Śruba laboratoryjnado przekierowań kąta do 36° do Multi Titanium Base multiSHIFT36°

      Laboratory Screw Muli-unit multiSHIFT36°

      Choose the implant system

      Quantity

      Price

      21 €

      Scanbody Multi-unit

      Scanbody Multi-unit

      Scanbody with an anti-reflex surface adapted to work with laboratory scanners. It includes an integrated screw that facilitates working.

      Wybierz system implantologiczny

      Quantity

      Price

      55 €

      Delivery

       60 €

      ALL PRICES DO NOT INCLUDE TAX

      Billing data

      Shipping data

      TOTAL: 0